HomeProductsYDF Incinerator20kg-1000kg Incinerator For Garbage Waste, Incinerator For Pet Animals

20kg-1000kg Incinerator For Garbage Waste, Incinerator For Pet Animals

Model: 20kg 30kg 50kg 100kg 150kg 200kg 300kg 400kg 500kg 750kg
Power: Diesel, Gas, Waste Oil, Lpg
Types: Floor-standing, skid-mounted, container-mounted
Certificates : ISO, CE

Key Feature:YDF incinerator delivers efficient, eco-friendly waste disposal. Smokeless and Odorless. Clean emissions, fast operation, and durable consturction design.

Introduction

Garbage Waste & Animal Incinerator

Incinerator For Waste Management 20kg-7000kg one day.

industrial waste incinerator,small waste incinerator

china waste incinerator,medical incinerator

YDF Waste Incinerator Advantages

1. Smokeless and Odorless, No Blank Smoke

High-temperature pyrolysis gasification technology+mixed incineration+burnout treatment.

Single/double/multi-stage flue gas treatment.

Enclosed burning, avoid secondary pollution.

2. High Temperature pyrolysis Process

Double chamber for incineration.

The chamber temperature up to 1300°C, retention 2 seconds.

3. Low Consump Cost

With first-class Itlay Baltur burner, ensure good qualtiy.

Primary combustion chamber automatically starts and stops, effectively utilizing high-temperature flue gas, save fuel.

4. Safe 100%, Easy to Install and Operate

Pre-assembled and well-debugged in our factory.

Simple to install the incinerator by Installation Steps.

Use ceramic fiber sealing tape rather than asbestos material. And high-strength refractory materials;

During the operation, auto ignition, auto control and temperature monitoring, automatic power cut off.

hospital medical incinerator,animal waste incinerator,china incinerator

How Incinerator Works

waste management incinerator,smokelss waste incinerator,gas diesel fired incinerator

YDF Incinerator Features

Our incinerator is provided with the currently most advanced incineration way, i.e., primary pyrolysis gasification + co-firing of surrounding wind +secondary incineration +burnout treatment.

YDF incinerator,medical incinerator,animal incinerator

1) The incinerator temperature reaches above the 1200°C continuously to ensure smokeless and tasteless and discharge up to standard.
2) Gasified incineration is used for burning syringe, paper waste, bandage, absorbent cotton and other medical wastes.
3) Gasified incineration, mixed incineration and burnout treatment ensures low emission standard of dust (lower than International standard).
4) Totally enclosed operation is suitable for treating infectious waste to avoid secondary pollution.

Kinds of Incinerators Showing

medical incinerator,animal waste incinerator,pet incinerator equipment

YDF Incinerator Cases

Yuanda Products Have Sold to 132 Countries & Regions, Global Sales & Services Worldwide

hospital waste incinerator,china medical incinerator price

Incinerator Package & Delivery

We will pre-install the incinerator in factory, also do the commissioning work, then all parts detachable to small pieces for delivery.

smokeless incinerator,household waste incinerator,hospital incinerator

Yuanda Incinerator Factory

1. Yuanda Company established since1956, mainly manufacture industrial boiler, incinerators.

2. Global sales with high quality products, with ISO CE ASME Certificates.

china incinerator,medical waste incinerator,gas diesel fired incinerator

YDF Incinerator

Environmental Friendly Incinerator

YDF incienrators are widely used for animal & waste incineration solutions. No pollution & Lower NOx emission.

Trustable Quality & Service

Yuanda company supply good quality incinerator equipped with famous baltur burner. Reliable after-sale service anytime.

Our Company

Yuanda Company has 70 years of professional manufacturing experience. With 18 years of export history, sales service cover 132 countries and regions.

Our Certificates

Yuanda Boiler products meet international certification standards ISO, CE, ensuring safety, reliability, and quality.

Technical Parameter

Models YDF-20 YDF-30 YDF-50 YDF-100 YDF-150 YDF-300 YDF-500
Processing Capacity (kg/batch) 10-20 20-30 30-50 50-100 100-150 200-300 300-500
Working Hours Per Batch Cycle* (min) 90-120
Primary Chamber Volume (m3) 0.2 0.38 0.5 1 1.5 2.4 3.5
Waste Feeding Gate Size (mm) 380 x 480 480 x 600 620 x 800 700 x 900 760 x 960 900 x 1100 1080 x 1280
Temperature () Primary Chamber 900
Second Chamber 1300
Smoke Residence Time (s) > 2 sec in second chamber
Applicable Waste Type Hazard Medical Waste/Consumables, Plastic, Paper, Domestic Waste, Animal Corpse, Electronic Component
Primary Burner - Baltur Italy BTL-6, 0.11kw BTL-6, 0.11kw BTL-10, 0.11kw BTL-10, 0.11kw BTL-10, 0.11kw BTL-10, 0.11kw BTL-14, 0.18kw
Second Burner - Baltur Italy BTL-10, 0.11kw BTL-14, 0.18kw BTL-14, 0.18kw BTL-20, 0.18kw BTL-20, 0.18kw BTL-26, 0.25kw BTL-35, 0.37kw
Total Diesel** Consumption (litre/h) 11-18 11-18 14-23 16-35 16-35 20-40 38-57
FD Fan Power (kw) 0.37 0.37 0.55 0.75 0.75 0.75 0.75+0.75
Applicable Voltage 380V 3Phase / 220V 1Phase
Outer Dimensions (m) 1.6 x 1.3 x 2.65 1.45 x 0.9 x 2.6 1.8 x 1.2 x 3 1.86 x 1.4 x 3.2 2.1 x 1.5 x 3.5 2.25 x 1.6 x 3.8 3.0 x 2.0 x 4.8
Chimney Dimensions (mm) φ280 x 6000 φ280 x 6000 φ300 x 9000 φ330 x 9000 φ380 x 9000 φ400 x 9000 φ460 x 9000
Weight (kg) 2000 3000 5000 6800 8000 9600 15000
Manufacturing Standard GB 18484-2020 (equals to EPA or EU standards)

Waste Disposal

General medical waste
Pathological waste
Household waste
Small or large pets
Dead animal carcass
Type I–Type IV red bag waste
General farm waste
Slaughterhouse Waste
Chickens, ducks, broilers, birds
Paper/Plastic waste
Hotel resort waste
......

Incinerator Advantages

medical waste incinerator,hospital incinerator

Devote To Use Easily

Easy operation, full automatically, one worker can operate it easily. Easy installation Well-debugged in factory. On-site Flange connection.
incinerator firebrick

Firebrick

The interior adopts high temperature firebrick, which can withstand high temperature 1700ºC, the outer wall adopts thermal insulation brick to isolate heat.
medical waste incinerator,hospital incinerator

High temperature pyrolysis technology

With the Italian baltur burner, the highest temperature can reach 1200 degrees Celsius, which can achieve the effect of sterilization and disinfection.
hospital waste incinerator

Smokeless & Odorless

Two-stage combustion technology, comply with national emission standards. Stable operation, low failure rate.

Contact Supplier

Related cases View more+

Send Inquiry

Write your request, we aim to offer catalogue & specifications & prices with 2hours.

Your Name

Contact Email *

Mobile

Message *