HomeProductsOthersPets Animals Incinerator

Pets Animals Incinerator

Product Brand: YDF Yuanda Incinerator
Product Model: 20kg 30kg 50kg 100kg 150kg 200kg 300kg 400kg 500kg 750kg
Available Fuel: Gas, Diesel, Lpg, Waste oil
Available Industries: For cats, dogs, cow, sheep, pig, horse. Widely used in Pet Cremation Business, Farm, Slaughter, Zoos, etc.

Key selling points:China Top Incinerator Manufacturer. Customized Design Service. Global Sales Cover 132 Countries & Regions.

Introduction

Pets Animals Waste Incinerator

 Volume in 20kg 30kg 50kg 100kg 150kg 200kg 300kg 400kg 500kg 750kg

Pet Animals Cremation Incinerators adopt high temperature heating technology. Harmful substances in waste are pyrolyzed and destroyed at high temperatures 1300°C. Importantly, incinerator equipped with waste gas treatment device, incinerator running eco-friendly.

Application: Widely needs in pet cremation business, in farm, in slaughter, in zoos, etc.

Noted: Customized service according your needs, please feel free to send your requirements.

pet cremation furnace,animal incinerator,farm incinerator

Incinerator Features

Our incinerator is provided with the currently most advanced incineration way, i.e., primary pyrolysis gasification + co-firing of surrounding wind +secondary incineration +burnout treatment.

pet incinerator,animals incinerator,farm incinerator

(1) The incinerator temperature reaches above the 1300°C continuously to ensure smokeless and tasteless and discharge up to standard.

(2) Gasified incineration is used for burning syringe, paper waste, bandage, absorbent cotton and other medical wastes.

(3) Gasified incineration, mixed incineration and burnout treatment ensures low emission standard of dust (lower than International standard).

(4) Totally enclosed operation is suitable for treating infectious waste to avoid secondary pollution.

china pet cremation furnace,animals cremation incinerator,animals cremation equipment

Easy to Install & Operation

We will provide full service for the equipment you have purchased, assisting with installation and providing operational guidelines. If you have any questions, please feel free to contact us.

1. All parts detachable to small pieces - convenient for transportation.

2. Flange connections reserved - easy to assemble with bolt at worksite.

3. Clear marks at wires & flanges - as assemble guidance.

medical incinerator,hospital incinerator,waste incinerator

Technical Parameter

Models YDF-20 YDF-30 YDF-50 YDF-100 YDF-150 YDF-300 YDF-500
Pet/Animals Weight (kg/batch) 10-20 20-30 30-50 50-100 100-150 200-300 300-500
Working Hours Per Batch Cycle* (min) 90-120
Primary Chamber Volume (m3) 0.2 0.38 0.5 1 1.5 2.4 3.5
Waste Feeding Gate Size (mm) 380 x 480 480 x 600 620 x 800 700 x 900 760 x 960 900 x 1100 1080 x 1280
Temperature () Primary Chamber 900
Second Chamber 1300
Smoke Residence Time (s) > 2 sec in second chamber
Applicable Waste Type Hazard Medical Waste/Consumables, Plastic, Paper, Domestic Waste, Animal Corpse, Electronic Component
Primary Burner - Baltur Italy BTL-6, 0.11kw BTL-6, 0.11kw BTL-10, 0.11kw BTL-10, 0.11kw BTL-10, 0.11kw BTL-10, 0.11kw BTL-14, 0.18kw
Second Burner - Baltur Italy BTL-10, 0.11kw BTL-14, 0.18kw BTL-14, 0.18kw BTL-20, 0.18kw BTL-20, 0.18kw BTL-26, 0.25kw BTL-35, 0.37kw
Total Diesel** Consumption (litre/h) 11-18 11-18 14-23 16-35 16-35 20-40 38-57
FD Fan Power (kw) 0.37 0.37 0.55 0.75 0.75 0.75 0.75+0.75
Applicable Voltage 380V 3Phase / 220V 1Phase
Outer Dimensions (m) 1.6 x 1.3 x 2.65 1.45 x 0.9 x 2.6 1.8 x 1.2 x 3 1.86 x 1.4 x 3.2 2.1 x 1.5 x 3.5 2.25 x 1.6 x 3.8 3.0 x 2.0 x 4.8
Chimney Dimensions (mm) φ280 x 6000 φ280 x 6000 φ300 x 9000 φ330 x 9000 φ380 x 9000 φ400 x 9000 φ460 x 9000
Weight (kg) 2000 3000 5000 6800 8000 9600 15000
Manufacturing Standard GB 18484-2020 (equals to EPA or EU standards)

Our Supply Equipment List

Inncinerator Body
Burner
Induced/Forced fan
Temperature Controller
Combustion chamber
Valves & parts
Cyclone
Distribution Cabinet
Pipes & flue
Bag filter
Chimney
......

Advantages of YDF Incinerator

medical waste incinerator,hospital incinerator

Devote To Use Easily

Easy operation, full automatically, one worker can operate it easily. Easy installation Well-debugged in factory. On-site Flange connection.
gas fired medcal waste incinerator, diesel incinerator

Low cost & Save money

when the temperature of the first combustion chamber reaches the set temperature, the burner is automatically shut down and the residual temperature is used for incineration.
medical waste incinerator,hospital incinerator

High temperature pyrolysis technology

The highest temperature can reach 1200 degrees Celsius, which can achieve the effect of sterilization and disinfection.
hospital waste incinerator

Smokeless & Odorless

Two-stage combustion technology, comply with national emission standards. Stable operation, low failure rate.

Ask For Catalogue

Related cases View more+

Send Inquiry

Write your specific requirements, we aim to offer quote with 2hours.